<LOGO>
FM Transmitter Measurement Report
Created: 2025-08-16 22-40-48
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 53 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 68 kHz 4701 0,4467
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,9 dBr 5,70 dBr 6,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 68 kHz MIN: 13 kHz % above 76 kHz: 0,4467 Acquired: 2025/08/16 22.39.45 Total samples: 4701 Equivalent time: 0:03:55 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: 6,5 dBr MIN: 4,9 dBr AVE: 5,70 dBr % above 12,2 dBr: 0,0 Last value: 5,5 dBr (2025/08/16 22.39.44) 22.26 22.28 22.30 22.32 22.34 22.36 22.38 0 2 4 6 Pm [dBr]